Part Number Hot Search : 
DS2505P 30011 02243 DS2023D 74HC564U AB310S 1018025 GRM21BR
Product Description
Full Text Search
 

To Download MDU3C-XXMC2 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 MDU3C
TRIPLE, HCMOS-INTERFACED FIXED DELAY LINE (SERIES MDU3C)
FEATURES
* * * * * * Three independent delay lines Fits standard 14-pin DIP socket Low profile Auto-insertable Input & outputs fully CMOS interfaced & buffered 2 10 T L fan-out capability
I1 I2 I3 GND 1 3 5 7 14 12 10 8
data 3 (R) delay devices, inc.
PACKAGES
VDD O1 O3 O5
I1 N/C I2 N/C I3 N/C GND
1 2 3 4 5 6 7
14 13 12 11 10 9 8
VDD N/C O1 N/C O2 N/C O3
MDU3C-xx MDU3C-xxA2 MDU3C-xxB2 MDU3C-xxM
DIP Gull-Wing J-Lead Military DIP
Military SMD MDU3C-XXMC2
FUNCTIONAL DESCRIPTION
The MDU3C-series device is a 3-in-1 digitally buffered delay line. The signal inputs (I1-I3) are reproduced at the outputs (O1-O3), shifted in time by an amount determined by the device dash number (See Table). The delay lines function completely independently of each other.
PIN DESCRIPTIONS
I1-I3 O1-O3 VDD GND Signal Inputs Signal Outputs +5 Volts Ground
SERIES SPECIFICATIONS
* * * * * * Minimum input pulse width: 100% of total delay Output rise time: 8ns typical Supply voltage: 5VDC 5% Supply current: ICCL = 40a typical ICCH = 60ma typical Operating temperature: 0 to 70 C Temp. coefficient of total delay: 300 PPM/C
DASH NUMBER SPECIFICATIONS
Part Number MDU3C-10 MDU3C-15 MDU3C-20 MDU3C-25 MDU3C-30 MDU3C-40 MDU3C-50 MDU3C-60 MDU3C-75 MDU3C-100 Delay Per Line (ns) 10 2.0 15 2.0 20 2.0 25 2.0 30 2.0 40 2.0 50 2.5 60 3.0 75 3.7 100 5.0
O1
O2
O3
NOTE: Any dash number between 10 and 100 not shown is also available.
100%
100%
100%
VCC
I1
I2
I3
GND
Functional block diagram
(c) 1997 Data Delay Devices
Doc #97039
12/12/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
1
MDU3C
APPLICATION NOTES
HIGH FREQUENCY RESPONSE
The MDU3C tolerances are guaranteed for input pulse widths and periods greater than those specified in the test conditions. Although the device will function properly for pulse widths as small as 100% of the total delay and periods as small as 200% of the total delay (for a symmetric input), the delays may deviate from their values at low frequency. However, for a given input condition, the deviation will be repeatable from pulse to pulse. Contact technical support at Data Delay Devices if your application requires device testing at a specific input condition.
POWER SUPPLY BYPASSING
The MDU3C relies on a stable power supply to produce repeatable delays within the stated tolerances. A 0.1uf capacitor from VDD to GND, located as close as possible to the VDD pin, is recommended. A wide VDD trace and a clean ground plane should be used.
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER DC Supply Voltage Input Pin Voltage Storage Temperature Lead Temperature SYMBOL VDD VIN TSTRG TLEAD MIN -0.3 -0.3 -55 MAX 7.0 VDD+0.3 150 300 UNITS V V C C NOTES
10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
(0C to 70C, 4.75V to 5.25V) PARAMETER High Level Output Voltage Low Level Output Voltage High Level Output Current Low Level Output Current High Level Input Voltage Low Level Input Voltage Input Current SYMBOL VOH VOL IOH IOL VIH VIL IIH MIN 3.98 TYP 4.4 0.15 MAX UNITS V V mA mA V V A NOTES VDD = 5.0, IOH = MAX VIH = MIN, VIL = MAX VDD = 5.0, IOL = MAX VIH = MIN, VIL = MAX
0.26 -4.0 4.0
3.15 1.35 0.10
VDD = 5.0
Doc #97039
12/12/97
DATA DELAY DEVICES, INC.
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
2
MDU3C
PACKAGE DIMENSIONS
14 12 10 8
Lead Material: Nickel-Iron alloy 42 TIN PLATE
14
12
10
8
.410 TYP.
1 3 5 7
1
3
5
7
.780 MAX.
.280 MAX. .290 MAX.
.820 MAX.
.020 .320 TYP. MAX. .130 .030 .018 TYP. .600 TYP. .200 TYP.
.015 TYP. .010.002 .018 TYP. .070 MAX. .600.010 .350 MAX.
.020 TYP. .300 TYP.
MDU3C-xx (Commercial DIP)
MDU3C-xxM (Military DIP)
.020 TYP.
14 12 10 8
.040 TYP. .270 TYP.
.010 TYP.
14
.020 TYP.
12 10 8
.040 TYP. .270 TYP.
.050 TYP. .320 TYP.
.430 TYP.
1 3 5 7
1
3
5
7
.090
.200 .600 .790 MAX.
.300 MAX.
.050 TYP.
.110
.200 .600 .790 MAX.
.350 MAX.
.110 TYP.
MDU3C-xxA2 (Commercial Gull-Wing)
MDU3C-xxB2 (Commercial J-Lead)
.020 TYP.
14 13 12 11 10 9 8
.040 TYP.
.010.002
.710 .590 .005 MAX.
.882 .005 .007 .005
1
2
3
4
5
6
7
.090
.100 .600 .780.020
.280 MAX.
.050 .010
MDU3C-XXMC2 (Military SMD)
Doc #97039
12/12/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
3
MDU3C
DELAY LINE AUTOMATED TESTING
TEST CONDITIONS
INPUT: o o Ambient Temperature: 25 C 3 C Supply Voltage (VDD): 5.0V 0.1V Input Pulse: High = 5.0V 0.1V Low = 0.0V 0.1V Source Impedance: 50 Max. Rise/Fall Time: 5.0 ns Max. (measured between 0.5V and 4.5V ) Pulse Width: PWIN = 1.5 x Total Delay Period: PERIN = 10 x Total Delay OUTPUT: Load: Cload: Threshold: 1 FAST-TTL Gate 5pf 10% 2.5V (Rising & Falling)
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
COMPUTER SYSTEM
PRINTER
REF PULSE GENERATOR OUT TRIG I1 I2 I3 DEVICE UNDER TEST (DUT) O1 O2 O3 IN TRIG TIME INTERVAL COUNTER
Test Setup
PERIN PWIN TRISE INPUT SIGNAL
4.5V 2.5V 0.5V
TFALL VIH
4.5V 2.5V 0.5V
VIL TFALL
TRISE OUTPUT SIGNAL VOH
2.5V
2.5V
VOL
Timing Diagram For Testing
Doc #97039
12/12/97
DATA DELAY DEVICES, INC.
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
4


▲Up To Search▲   

 
Price & Availability of MDU3C-XXMC2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X